Sub-Visible Particle Analysis in Parenteral Formulations

gsk-sub-visible-particle-analysisCharacterization of sub-visible particles in parenterals was formally addressed by United States Pharmacopeia (USP) Official Text <788> in 1975. At the time of its implementation, USP <788> was primarily concerned with foreign matter, such as rubber stopper pieces, that might not be distributed through the blood system easily.  USP <788> states that sub-visible particles above 10 micron and 25 micron must be monitored and reported.

Limitations of Light Obscuration and Its Consequences

Sub-visible particle analysis is typically done using a light obscuration instrument, which provides a total count of all particles detected greater than 10 µm and 25 µm. While it meets U.S. Food and Drug Administration (FDA) requirements for counting particles under USP <788>, there are increasing concerns that this method may not provide a complete picture.  Knowing exactly what particles are in a sample and how many of each type is vital to meeting strict quality demands, accelerating development timetables, minimizing risk and, ultimately, to the success of the product.  

Our blog post "Imaging Particle Analysis Reveals Higher Concentrations of Sub-visible particles Compared to Light Obscuration Technique" discusses the voluntary withdrawal of Omontys® — a peginesatide — from the market less than a year after product launch.  The peginesatide samples passed USP <788> limits for particulates. The methods of particle analysis used by the FDA task force suggest the FlowCam can differentiate protein aggregates, silicon oil, and air bubbles from other particles that would otherwise go undetected using light obscuration alone.

After using light-obscuration instruments to count particles in a new parenteral product formulation, a project team at GlaxoSmithKline (GSK) in King of Prussia, Pa. found that the technology provided little useful information about the nature of those particles. The light obscuration method yields a read-out of particles counted in the sample, but is unable to shed light on the nature of the particles. This technology has difficulty determining the actual number of particles present as transparent or translucent particles may be excluded from the analysis. Additionally, a light obscuration instrument is not capable of differentiating one type of particle from another particle, such as an air bubble or foreign fiber from an aggregated protein. If the particles are not identified, differentiating the actual number of product-related particles can be a difficult task.

The Benefits of Imaging Flow Microscopy Over Light Obscuration

A GSK team member with expertise in particle analysis reasoned an imaging particle analyzer that takes digital images of each individual particle detected in a sample would reveal the nature of the particles and assist in a better assessment of the product quality. The project team evaluated a range of available technologies from different vendors. The list of criteria relevant to particle analysis was extensive, including the volume of sample needed to obtain statistically significant data, how much set-up time is required, the adjustments needed to yield useful images, and whether additional steps were required for qualification and validation.

After testing, the team concluded that a FlowCam, set up quickly and with small samples, yielded high-resolution images in real-time along with the particle size, count, shape, and other measurement parameters. The system provided images of aggregated proteins, longitudinal fibers, round, silicone oil droplets, and air bubbles, as opposed to counts and graphs offered by other systems. It also could detect opaque, translucent, and transparent particles and automatically discern one from the other using pattern recognition software. The FlowCam could also determine why the sub-visible particles were present and whether they were related to the product formulation or to sampling technique.

sub-visible-particles-in-parenteral-formulation

The FlowCam system takes measurements based on actual images of each particle as opposed to measuring based on estimated particle counts and sizes. (See also: Direct vs. Indirect Particle Size Measurement) For particle analysis in the range of detection of 2.5 µm to 3 mm, the FlowCAM yielded the highest quality images of any instrumentation tested, the team concluded. The accompanying VisualSpreadsheet software enables users to filter and sort particle data based on different criteria while a sample was running and save them in libraries for future comparison. Individual images of interest could be selected with a mouse click; irrelevant images such as air bubbles could be deleted, while the raw data remained intact.

Customer Spotlight: Glasko Smith Kline Buys FlowCam

Based on the evaluations, GSK decided to install a FlowCam VS-I, which was developed to analyze parenterals for proteinacous particles. The model’s autoimage mode triggers the camera to capture an image each time a particle passes through the field of view in the flow cell.

Since installation in February 2010, the FlowCam has been in continuous operation to automatically uncover any trends in the number and/or type of visible particles present in the samples. The project team shares information with colleagues in other departments around the world by emailing the images and data. Quality control managers, who rely heavily on particle analysis data, view the particles on monitors. The FlowCAM data is also being used to verify the accuracy of the data generated by visual inspection.

While light obscuration systems require at least a 25 mL sample to yield enough data to be considered statistically significant, the FlowCam requires only 1 mL of sample to run an analysis. With samples often provided in 300 µL ampoules, the FlowCam has reduced the number of required samples from more than 800 per batch to three, while also reducing sample handling and preparation requirements.

The ability to see the actual particles in parenteral formulations, to see their morphology, and to automatically differentiate one type from another marks an important advance in parental drug particle analysis. At GSK, imaging particle analysis using FlowCam has been integrated into its testing program for development of protein-based parenteral drugs.

The FlowCam is optimized for imaging and analyzing transparent and semi-transparent particles using both Light and Dark Thresholding. Download our free Thresholding Whitepaper by clicking on the box below. 

FlowCam Light and Dark Thresholding Whitepaper 